An experimental investigation on thermal striping. Mixing phenomena of a non-buoyant jet with two adjacent buoyant jets as measured by ultrasound Doppler velocimetr

Download the full PDF ➡  


Read the paper below ⬇️


An experimental investigation on thermal striping.

Mixing phenomena of a non-buoyant jet with two adjacent buoyant jets as measured by ultrasound Doppler velocimetry

A. Tokuhiro



planar vertical jets, one unheated surrounded by two heated jets. Velocity measurements of a re/erence slngle-jet and the triple-jet configurationwere taken by ultrasound Doppler velocimetry while temperature data were taken from 39 thermocouples traversed vertically. We found from a hydrodynomic perspective that beyond the exit region, our single-jet data oehaved like previous singIe- set data Ir *n».*ast u^.•- ip!•- •.: -•xi:f0i:•0 for cxam‹ipie, up ie' zu ines me root-mean-square velocity values in the downstream regions, especially in between the heated and unheated jets In particular for equal jet exit velocities (3 jets), U„t=0.5 mls and a temperature difference between the jets, AT =T„,-


    1. to 4.5, where Db is the hydraulic diameter of the exit nozzle. Spanwise the mixing span a range, x,‘ D5 - 2 25, centered about the unheated jet; that is, the regionbetween the heated and unheated jets.17 I

      List of symbols

      Symbol

      Unit


      D

      10”' m

      hydraulics diameter of the inlet channel

      Gr

      -----

      Grashof number, = (g§AT z' ’v' )

      L

      10 ' m

      length of the inlet channel

      Pr

      -----

      Prandtl number. — ( v'n )

      Re

      -----

      Reynolds number of inlet channel, — (LD3/v) or (Hz/v)

      Ri

      -----

      Richardson number, = Gr/Re

      T ‹ .T„

      ,ñJ, f [ °C)

      temperature of heated, unheated jets, temperature difference between the

      two at the exit, root-mean-square of temperamre

      ctr,max
      V10 3 mls characteristic velocity, velocity at the exit of the nozzle10°' mls maximum centerline velocity of the velocity profile 10 ' m’s root-mean-square velocity of w-component10 “ m transverse (cross-stream) coordinate10”' m axial coordinate as measured from jet exit and axial core length m2 s thermal diffusivity1/K coefficient of thermal expansion mz’s kinematic viscosiy

      Introduction

      Thermal striping refers to random thermal cycling of reactor structures and components as a result of fluid-strucmre interaction. that is. sniping is likely a description of the cold and hot (thermal) stripes or plumes and jets that a solid boundary must withstand due to preferential ‹rr inefficient mixing of typically coolant flowing through and exiting the core. The net result of this striping is undesirable since thermal fatigue of materials can lead to structural and material failure. Thermal striping as a phenomenological problem in LMFBRs was already recognized in the early 1980s by Wood (19801, Bannings (1982) and has subsequently been considered by Betts, Bourmau and Sheriff (1983), Moriya et al. (1991) and in recent years by Muramatsu (1994).We note here that, although the phenomena taken as a whole involve fluid-structure interaction, the analytical and experimental efforts have generally been divided into structural and thermal-hydraulic investigations. In the present work, w'c focus strictly on the thermal-hydraulic aspects; thai is, mainly the coovective mixing of a multiple number of jets at different temperatures, The number of jets can range from a single-jet, which has been most extensively studied, to two jets flowing side-by-side, at a relative angle or co-axially and with a relative velocity (anñ'or temperamre) to each other. In fact co- axial jets of sodium have been investigated by Tenchine and Nam (1987) while Tenchine and Moro
      (1995) compared the results of sodium and air jet experiments, Investigation of more than two jets seems to be rare. Thus besides its relevance to LMFBR thermal-hydraulics, a study of a multiple number of vertical jets at either the same or different densities (temperatures), may be of general interest to the heat transfer community.
      In the present smdy, we carried out water-based experiments in a test facility simulating the mixing of one centrally located jet sandwiched by two adjacent and buoyant jets at higher (hotter) temperature. One objective of the study was to demonstrate the applicability of ultrasound Doppler velocimetry for velocity measurements. By applicability we mean velocity measurements in the flow field of relevance. Subsequently we first obtained and evaluated the hydrodynamic information concerning the nature of mixing between thermally-stratified jets, Then with the addition of temperature data we u'ere able to assess the thermal-hydraulics2

      Experiment

    2. Experimental facility

      Figure 1 shows the experimental loop including the test section. Except for the test section, the rest of the facility functions as a support system shared by Evo other experiments. The facility thus consists of the thermal striping test section set within a larger rectangular tank, a loop heater/exchanger for supplying hot water, a head tank in order to control the water-level, a filter to extract contaminants within the loop, an air-to-loop heat exchanger for supplying cold or cooled water back into the loop as well as a general purpose lab water supply tank. Several mrbine flowmeters as well as orifice plate type devices, a system of valves and all the connecting piping are as depicted.A more detailed view of the test section itself is shown in Figure 2. The test section is immersed within a rectangular tank measuring 24 8W x 2438H x 67 I D [W-width. H-height. D-depth, all mm], and is itself a partially enclosed rectangular region measuring 400W x 950H x 176.5D, As noted in the top view, two acrylic plates sandwich the four rectangular blocks thereby restricting the spread of the exiting jets in these directions, The idea was to constrain the jet to a finite width and to “view” it as quasi two-dimensional within this geome . The right and left sides are however. open so thal even with overflow mechanism at the top of the test section there may be some recirculating flow through the sides. A prominent feature of the tank is the large viewing glass windows on both the Jenf, back and right side of the tank. This feature was included primarily for laser-based measurements and flow visualization techniques. Below the test section are three rectangular channels defined by four equally rectangular blocks. The central channel functions as the “cold” jet while the adjacent Evo are “hot”. The hot and cold jets are supplied from separate sources, the cold source being centrally simated, flowing first through an expansion and then through a flow constriction. The hot source is on the other hand supplied from the right-hand-side into a lower chamber. The flow they weaves its way past the173cold pipe and enters symmetrically through a one-sided rectangular constriction, The exit of the nozzle is a block elevated 75 mm from the reference gi oundplane of the tank.The other prominent components of the test facility is the traversing thermocouple array and the UVP transducer holder fixed to the left arm of the traversing mechanism. A schematic is shown in Figure 3 along with the exit blocks. The moving mechanism consisted of two vertical and parallel pillars (OD 45mm), between which a “bridge” served as a mounting bracket for the thermocouples, This bridge is fixed and moves up and down with the pillars. The traversing thermocouple array consists of 39 thermocouples facing vertically downward and horizontally spaced 5 mm apart over a 190 mm span. The last 5 mm of each of 39 thermocouples are directly exposed to the flow, while beyond this point the T. C is insulated for a length of 50 mm. The T/Cs are threaded and bonded to an horizontal arm and contained either in the right or left arms. The Evo arms enter through the top of the rectangular tank. The thermocouple are T-type, constantari copper-nickel with an expected measwement error of 0.5*C. Operationally three T/Cs malfunctioned (No. 5, 6, 14 numbering from lefi) and could not be used for data acquisition,
      (1992) monitor with a single, Delrin-encased (temperature limit 80°C) piezo-electric transducer [TDX] operating at I MHz. The transducer had an active crystal diameter of 6 mm. The UVP works on the principle of ultrasound Doppler echography; that is, the position and velocity information are evaluated respectively from the detected time-ot-flight and the Doppler-shift frequency at each of 128 locations. From these 128 locations, a componental velocity ’profile is constructed along the measurement line (ML) of the ultrasonic beam. By componental it is understood that the velocity vector oriented either toward or away from the face of the transducer (from the sign of the Doppler shift) and the magnitude is measured at eacn of the 128 “coin-1iks” volumetric elements during each of the 1G24 measurement intervals, The real-time corresponding to 1024 measurement intervals is adjustable depending largely upon the preference (and experience) of the user, though it should be based on the phenomenon of interest in the flow; that is, based on estimates of the time-scales associated with various transport phenomena, the user is able to select either a short or long time span between measurements. The UVP can thus detect transient phenomena during a minimum time-span of 0 msec to minutes and hours. The device has been developed and tested most notably by Takeda (1986. 1991a, 1991b).The ultrasound is reflected from tracer particles. typically a plastic powder with a nominal size of 50- 100 km (p = 1.02 kg’m3), that are added to the test medium (water). One should note that the inherent assumptions using this measurement technique are that: I) the tracer particles accurately reflect the velocity profile of the liquid state and 2) the modification of the flow field due to addition of tracer particles; that is, the particle-to-fluid interaction, is of minor consequence to the measured profile.174Additionally, it is assumed that particle-to-particle interactions are negligible since the concentration of tracer panicles, i.e. on the order of 100 grams per 4000 liters (3988) of water, is physically very low. Finally, regarding the former, we assume that there is no slip (relative) velocity between tracer particle and liquid; that is, the particle moves exactly as a fluid element would, as dictated by the initial and boundary conditions of the flow As for the positioning of the transducer, it was held in place by athrough a 4m long cable. The ty'pical measurement time was of the order of 1-3 minutes
    3. CondñionsofUYPandtemperaturemeasurements


experiments was 0 5 mls with an estimated error of 0.1 mls. The temperature difference between the cold and each of the hot jets was held to 5°C in all cases with an estimated error of 0.75°C. IJVP measurements were conducted with the transducer fixed at either the right or left locations with respect to the jet(s) (see Figs 2, 3). Measurements were taken axiallv, along the z-axis, at 5 mm intervals up to approximately 550 mm above the imaginary “0 "-p/are in most cases For all the data present here, the UVP transducer was oriented at an an''!e n* ! (1° *v:'ri: r•.sp.•st to :i:.• i:or:zon:a!. Ti:c selection of use i 0° angle was in reality an experimental compromise between a sufficient number of axial locations, which we sought in order to follow the flow development, and the detection of the larger, axial vector component relative to the horizontal component of the actual jetting fiow.


Results

175

temporal (time) dependence. Note that in the present set-u p the axial coordinate is the z-axis and the spanwise or width-w'ise distance is the x-axis Finally in order to facilitate our presentation, we refer to the buoyant jets as the “hot” jets and the non-buoyant, central jet as the “cold” jet.


3.2 UYP velocity p,of1e&: SinglejeCand Triple]et


Figure 7a) shows a representative set of average velocity profiles of the single-jet taken by the UVP. The axial distances (z) have been chosen to clearly display the changes in the profile with downstream locations and thus represents the distance from the groundplane as indicated in Fig. 3 The abscissa depicts the 128 channels (0-1 27) along the ultrasound beam, a distance equivalent to 284 mm as noted. In Fig. 7b) we show one profile (z=45 mm) and its associated standard deviation profile in orher to explain details of the profile itself. The actual profile as measured for example by the transducer depicted in Fig. 3 is the inverted image of Fig 7b); that is, recall that with respect to the transducer, flows coming toward it are “--” (negative) and those flowing away are “-” with regard to the sign of the Doppler shift. This does not in any way change th.e information content of the depicted velocity pt ofiie ’?’e thi:3 sec :i:at a prom:n•.at f•st'ur.° is the peak.eel jet-like profile in the central region. Additionally, to the sides of this central region are the entramed-flow regions which show flow of approximately equal magnitude and on-ovsrage of opposite sign with respect to the transducer We say on-average here because the mixing layer-generated untrained flow dynamically changes direction and magnitude during the measurement period We observed this while analyzing many sets of 1024 profiles per set of UVP velocity data. However, on average they are of opposite sign We note that overall although narrower the velocity profile in Fig 7b and in Fig. 6 are similar Returning to Fig. 7a) we have anificially in verted the right-hand-side of the profile taken at z—45 and shown it as a dotted line to qualitatively u lustrate the simi larity with the developing jet depicted In Fig. 6 As for the standard deviation distribution the twin peaks and the valley in between appear to characterize the edge


Asamahezocomparisonbenveenou(1ohenna)smg1ejetdaawiit|iatkomqat1nveniaion we show in Figure s the axial decay of the centerline velocity with those of investigators as noted The data of past investigators have been extracted form Cheremismoff(1986) and are represented by linear regression lines above the so-called velocity core length, z„,. The core length corresponds to the axial point below’ which the data assumes a quasi-constant value (y, - 4) To the best of our knowledge the past data are for isothermal air jets Note that there are variations in slope and magnitude even for identical fluids. Except for the exit region ( z < 0 8) for which Cheremisinoff presents no data our data is consistent with past invesogations.

Figure 9a) shows a representative set of average velocity profiles of the triple-jet at several coincidental axial locations as those in Fig. 7. Due in part to the number of jets (3) and the interaction between them the individual profiles are much more difficult to discern in this figure. R'e also include the profile near the maximum measured location, z = 535 mm, instead of at z = 350 and also provide data at z — 195. W'e next present in Fig. 9b) one profile and its associated standard deviation distribution at z = 45. The velocity profile taken here with the transducer at the right is clearly distorted, gspecially the left jet. ’the approximate location of the exit nozzles are kdicated by triangular symbols on the x-axis. Note that similarly to Fig. 7b) the core and edges of each jets, certainly for the left and center jets are identifiable from the standard deviation profile. The left edge of the right jet is also evident. While details of the distorted profile are discussed later, we present respectively in Figs. 9c) and d) a composite triple-jet velocity profile and an idealized profile. The composite profile was constructed by taking one-half of the profiles from respectively the left and right transducer orientations and joining them at the center,


Figure 10 shows the calculated Root Mean square (RMS) velocity distribution versus axial distance for both the single- and triple-jet, the latter for both left and right UVP transducer orientations. The triple-

identical, it is likely that thermohydraulic conditions were not exactly’ reproduced. The single-jet data is for an isothermal jet. The average exit velocity in all three cases was 0.5 m’s. Figures 11a)-f) then show the estimated spanwise distribution (x-direction) of the ratio of the triple-jet RMS to that of the single-jet RMS with the axial location as the parameter. The data are shown in groups of feur for clarity while for each type ofjet, the RMS value has first been normalized by its own spanwise average velocity. The triple-to-singlc jet RMS ratio has been calculated at g spanwise regions, each containing velocity data (16 points) over a 35.5. mm span. Eight regions were selected since it was thought that a distribution consisting of 128 points would reveal fine detail not necessarily characteristic of the spanwise variation which might be revealed in a segment-wise average. Our objective was thus to qualitatively or semi-quantitatively reveal the difference in the normalized RMS distribution of the triple-jet versus the single-jet. After varying the number of regions we settled an 8 regions as representative of the spanwise variation.

3.3 Temperature data


The spanwise temperature distribution at selected axial locations is shown in Figure 12. Several points to the left are missing due to malfunctioning thermocouples. Each point represents a temperature averaged over 20.5 seconds containtng some 1025 samples. We note that the spatial resolution and span over which the velocity and temperature data were taken did not coincide; that is. the UVP data was taken over a length of 284 mm with a resolution of 2.2 I mm whereas the theriuocouples span 190 mm at 5 mm intervals. We mention this fact because it is of significance when combining velocity arid temperature data. We next show in Figure 13 the corresponding spanwise distribution of the standard


17?

deviation at selected axial stations. Compared to Fig. 11 the z-locations have here been selected to show the gradual change near the exit (z = 20. 30, 40 mm) and at or near the maximum magnitude (z = 120. 130, 140 mm) using Fig. 10 as a suide. Figure 14 is the temperature equivalent to Fig. 1fl for velocity. Except that here we show the normalized RMS with the normalization factor being the spanwise averaged temperature.


Next in Figure 15 we show an iso-contour plot of the calculated turbulent heat flux distribution. The figure has been generated from separate calculations of u and i’, which respectively represent the velocity and temperature fluctuations as a function of (x,z). We have equated w ' and i to the RMS values as presented. Recall that the quantity w is not strictly the z-component of velocity fluctuation since the UVP-TDX was oriented at 10‘ with respect to the horizontal; that is. it includes primarily the component but also a small contribution from u In addition since the traversed increments for temperature and velocity were of different sizes. some interpolation had to be performed in order to fill-in missing data. As a matter of approach, the coarser (larger traverse increments) temperature data was taken as the basis onto which the finer velocity data was adapted, so that interpolation would be minimized. Fortunately, both the temperature and velocity data have nearly equivalent re.‹efuiion up to

x - 1SV), •z..h.ieh. s!so appear tn hg the refine rif relevance frir thermal mixing. It is clear

from the figure that beyond z 300, the distribution shows largely linear patterns (straight lines) which are the result of sparsely recorded data points and interpolation between these points. We thus settled on a semi-quantitative presentation of the turbulent heat flux distribution.


Finally in Figure 16 we plot the frequency versus the axial distance of the first six peaks ordered in terms of “power” for the triple-jet. The frequencies were generated by applying a fast Fourier transform without any windows to the velocip profiles and characterize the hydrodynamic fluctuaaons inherent in our flow. They represent the flucmations along the ultrasound beam. The ordering based on the power gives a measure of the turbulent kinetic energy associated with each frequency of the flow.


4

Discussion of results

4.1 UVP velocity profiles: Single-jet and Triple-jet


The images in Figs. 4 and 5 were presented to orient the reader and to facilitate the discussion to follow. A brief introduction regarding a way to view the UVP measured velocity profile was given based on single-jet data (Figs. 7), We subsequently verified that the our single-jet data, for example the centerline decay velocity was consistent with past experimental data (Fig. 8), even though most of the past data used air as the test medium. We then presented the average velocity and its associated standard deviation profiles for the triple-jet in Figs. 9a) and b).

In Fig 9b) we note first that the jet exits are spanwise located along the abscissa at approximately x -


the right and center but each with a shape similar to a single-jet profile The profile corresponding to the right jet (x - 32). as taken from the right however, shows a distorted, twin-peaked shape. And


profile. This inconsistency, that the distorted portion of the profile corresponds to the jet closest to the transducer, may be due to inadéquate arnplification of the echoes returning from the ultrasound wave reflecting tracer particles. That is, the linear amplification tversus distance from the transducer) which has been applied. although adequate for the distant channels (measurement volumes), appears insufficient for the (near) jetting region in question The other distinct possibility is that due to the 10° orientation of the transducer, different axial segments of each jet is detected. As mentioned the I 0º angie was in reality a compromise between including the contribution from the expectedlj larger vertical component of velocity along the ultrasound beam (measuring line) to that of measuring as near identical axial segments (same z-locations) of the three jets as possible. In Fig. 9c) we have sketched the transducer at both tight and left positions and also depict some of the just so-described details Finally in Fig 9d) wc present a composite profile of the triple-jet with the left and right one-half portions taken with the transducer respectively frnm the night anü !eft Ti:-° profi!•. o:'-•r!aps :ü ci:au-ci number at the center and represents an undistorted profile of the triple-jet


d.2 Comparison oftriple-jet to single-jet velocity data


Fig. 10 depicts the axial distribution of the normalized FUS for both the single- and triple-jets. the latter for both right [R] and left [L] transducer orientations. While there are some differences in the triple-jet data the marked contrast is between the single- and triple-jets. In fact the triple-jet reaches values larger than what one might expect as a “‘rule-of-thumb”; that is, roughly three times the single- jet value (see 2 < z/D, 7) Furthermore, the overall trend is different than the single-jet, which in comparison steadily increases up to z/D, - 11 where it appears to reach a quasi-constant value We note thai in Gebhardt ct al (1988) the fully-turbulent region of an isothermal (or non-buoyant) axisymmetric jet, based on the axial distribution of the turbulent intensitv, is reached at approximately 10 diameters downstream from the exit If we can expect our quasi-planar jet to behave similarly then, for our average exit velocity-based Reynolds number of Re - 2 x 10‘, our datum points have yet to reach a fully-turbulent state Equally, that the peak Intensity spans our measurement limit of z/Dt 15 is different from the quoted work The triple-jet in contrast, beyond a local minimum at z/Dt - 1.2. shows a rapid increase to a maximum value at z'Db - 6 and thereafter an equally rapid decrease to a quasi-contact value at nDt 9. From these data alone one could partially conclude that the “hydrodynamic” mixing of the hot and cold jets occurs within 2 to 10 diameters of the exit nozzle Bj


hydraulic Interestingly enough, beyond z'Dt > 10 the isothermal single-jet's RMS exceeds that of the


1 79

thermally-stratified triple-jet's. Since data of an isothermal triple-jet and/or a buoyant single-jet are not available at present we could not isolate nor fully assess the influence of (thermal) buoyancy on the turbulent mixing process. However, it does not appeal to physical reasoning that an isothermal triple- jet's RMS value would suddenly decrease to less than a single-jet's in comparison, So we believe it likely that either the energy content of the buoyant triple-jet is depleted due to thermal mixing anñ'or some form of turbulence suppression occurs; that is. something analogous to re-laminarization of turbulent mixed connective flows near the laminas-to-mrbulent transition.


Since Fig. 10 depicts the spanwise averaged RMS-values, it suppresses any details of the flow especially in-between the jets. We thus show in Fig. 11a)-to-f) the ratio of the normalized RMS of the triple jet to that of the single jet. Both the single- and triple-jet RMS-values are normalized by their respective spanwise average velocities. The thinking behind this particular way of aata presentation was as follows. Since we are primarily interested in the convective mixing at the edge of each jet where potentially the largest temperature gradients are located. we do not necessarily need to look at the fine details of the spanwise velocity profile (for example Fig. 9a), In other words. even though this data is available. we know in adva..ce some regions of interest of the triple-jet's configuration. Therefore.

•*.i:i!e •i. e expert s iIu•0ua*ingve!ority Signature within each of the 128 measurement volumes, we can afford to spatially average (or lump) the velocity level in segments; that is, we can spatially-average over a number of volumes and select the number of segments representative of the flow. Figs. 11a)-f) therefore show the triple-jet data taken from the right, normalized by the single-jet, also taken from the right-side. The legend in each figure shows the axial location at which the ratio was calculated. Since there was a discrepancy between single- and triple-jet measurement locations, a calculation of the RMS ratio at the same axial position was not always possible. Thus. where the locations differed, the axial locations are as noted,


It is clear from these plots that from z 70 (z/Of 1.96) to about z 200 (z D 5.6), the RMS of the triple-jet is larger ( 1) than that of the single-jet. In fact, between 95 z 120 (2.66 z/D3 3.36), the ratio can be as large as 20. Specifically the large values are reached typically in regions “3" and “6" which correspond respectively to the range 154.4 x 189.9 mm and 225.4 x 260.9 mm from the face of the transducer positioned at left (see Fig. 3). These regions substantially overlap the width of the two exit nozzle blocks located in-befu•een the hot and cold jets. This gives strong support to localizing the thermalhydraulic mixing of our thermally-stratified jets. On the other hand, beyond z - 300 (z D3 8,39). except for the left-most and right-most regions where the ratio is nearly one or slightly larger, the cenoal region show’s a value of less than one. This trend is consistent with Fig. 10 for z/D, 10. This means that the dynamics of connective mixing below z 300 are such that the resulting RMS of the triple-jet especially in the region adjacent to and including the cold jet, falls below that of even an isothermal single-jet. In other words, just based on the RMS velocity data the


1f›0

thermal mixing appears to take place (transverse to the flow of the jet) such that the turbulence is in effect “depleted” in the central region.


4.3 Temperature measurements


We next present in Figs. 12 and 1 the spanwise average temperature and its associated standard deviation profiles respectively at selected axial locations. The axial distances were selected for clarity in presentation and to correspond as much as possible to the velocity profiles. Note that at z = 20 (mm] the profile clearly indicates the presence of a central cold jet ( T 25.5“C) and two hot jets (T 30.8‘C), while in-bebveen (to the right and left of z 90) the temperature assumes the “approximate average” of 28‘C over a span of 30 mm on either side of the cold jet. Near the regions of the individual jets, the temperature gradient is very sharply defined. At a distance 50 mm further downstream. at z — 70 mm, the “mixing” of the thermally-stratified streams appears well under way and the profile reflects this as the gradients (to either side) between the hot and cold jets have decreased (e.g, 100 < x < 108); that is, the temperature gradient, although still larger than at successively higher axial distances, is smaller in comparison to z — 20, By z = 180 tiien. the temperature gradients between the hot/cold sueairis ai‘e iiiuuii >iii'o1icr anti overaii, ihe nermai mixing brings about a "flattening of the spanwise temperature profile. From z = 20 to 180, the axial center of the cold jet has increased in temperature (from 25.5°C) to nearly 29°C while the hot jets have decreased in temperature from 30.8°C to 29.5°C. which is a smaller absolute change than for the cold jet. The apparent reason for this is the presence of two hot jets which transfer heat to the single cold jet, Beyond z — 180 the temperature profile does not change significantly and resembles the profile at z = 180. Thus except for z 500 we have not shown the profiles at z = 200, o00 and 400 mm.


As for the standard deviation distribution, the profile shows for example at z = 20, a “twin-peaked” profile similar to Fig. 7b for velocity while in between the jets there is a “plateau” or flat region describing temperature uniformiq. At z = 0 however, the profile is already changing as the magnitude of the plateau regions increases relative to the twin-peaks of the central jet. This trend continues at z = JO. One can also see that the profile near the het jets does not change US mllch as the region surrounding the cold jet. This appears to be an early indication of the thermal mixing at these lower axial locations. By z = 80, the overall fluctuation level has increased markedly and the profile itself has changed dramatically. In fact, most of the thermal fluctuations are clearly in between the hot and cold jets, while there appear to be smaller “peaks” located on the far side (see right jet, z 164) of each of the hot jets. Note too that the relative width of the cold jet's core region remains fairly unchanged (compare z — 40. 80) and that a local minimum value exists up to z 140 but no longer at z = 180, This means. at least qualitatively, that the thermal mixing has trot yet reached (spanwise) the core of the cold jet at 80 < z 140. This is, however, no longer the case at z — 180 where the “defect* seen at z < 140


.

has all but disappeared Beyond z = 180 the profile assumes a gradually decreasing Gaussjan-like distribution such that at z — 500. the magnitude is less than l% of the ai'erage at that location


We asserted from a hydrodjmamic point of view, based on the RMS velocity data, that mixing most likely takes place over the axial span, 70 < z < 250 (2 < rDt < 7) and in particular, in contrast to the single-jet the mixing is especially accentuated in the region in-between the jets. We would thus expect much of the thermal connective mixing to occur in-bcaveen the cold and hot jets as well \\'e first show however, in Fig. 14 the normalized RMS value for temperature along the axial direction This figure shows that consistent with the RMS data for velocity•, the RMS for temperature reach their largest values, say over 1%, along 60 < z < 300 mm (1.68 < z/Q, < 5.4 ). The axial span over which thermal


For the condinons given in this work the non-dimensional groupings. mainly the Reynolds (Re). Grashof (Gr) and Richardson (Ri = Gr / Re° ) numbers calculated at the mean exit temperature of

27.S°C and based on the hydraulic diameter Db were as foI-lows- Re 2.1 x 10‘, Gr — 8.75 x 10' and

Ri = 1.98 x i0'’. IN the Ri-ntimber is tak°+n as the ratio of buoyancy to inertial forces, then conditions at


1.20, 535 mm: Ri (z = 120) = 6.89 x 10*° and 15.5 x 10*°. So it does appear that the buoyancy force increases relatively to the inertial force from an axial location where mixing is vigorous ( z — 120 mm) to where it is essentially complete (z = 535 mm). However, our flow at z —535 mm is still predominantly jet-like and not plume-like.


In Figure 15, we presented an iso-contour plot of the estimated turbulent heat flux distribution that we derived from separate calculations of the RMS for velocity, w ’, and temperature. I’, both as a function of (x,z). We previously noted true nature of v’ due to the inclination of the ultrasound transducer. It is by coincidence that the spanv'ise turbulent heat flux is the one calculated and is also the quantity which may hold more significance in terms of evaluating the thermal mining. That is, if the spanwise mixing is efficient and thus the heat energy is dissipated. the thermal striping impact is lessened on any solid boundary which the flow encounters. In other words, at a given axial location, the uniformity in the spanwise temperature distribution is a measure of the thermal mixing which has taken place below it. So in spite of the compromises made m matching the velocity and temperature fieIds, the figure strongIy supports our view that thete is sgnificant convechve mining of thermal energy contained in the two heated jets mostly to the cold jet. This is carried out for an average exit nozzle velocity of 0.5 mls and AT — Tt„ „ - T„; „ — 5°C. along an axial span 70 -z - 160 mm or when non- dimensionalizing with the exit nozzle's hydraulic diameter, z/D;, - 2.0 to 4.5. In addition, the corresponding spanwise ’idth *'here most of this mixing takes place is ’Db 2.25 centered about the axes or the cenaai (cara) jet.

Finally in Fig, 16 wc have shown the axial distribution of frequency of the first six peaks ranked in terms of their “power” which is a measure of the mrbulent kinetic energy associated with the flow. lt seems clear that there are two frequencies, one at approximately 2.25 HZ and the other at 0.7 Hz, dominant in the flow with a transition from the higher to lower frequency at roughly z = 300. Additionally the frequency mode/— 2.25 Hz is established within the fast z < 80 mm from the jet exiis and coincides with the span over which thermal mixing is thought to occur. lt is therefore lîkely that especially for a low Prandtl number fluid like sodium (Pr 0.001) that both hydrodynamic and thermal fluctuations are characterized for a flow of this type (and under similar conditions) by frequencies of order 2 Hz. That is, if our water data primarily yields frequencies 0.7 and 2.25 Hz, with the large thermal diffusivity (and smaller viscosity) of sodium we would expect “thermal frequencies” in a similar range. In fact thèse two frequencies are within the range obserred by Brunings (1982), 0.1 to 2,d Hz, who measured temperature fluctuations in a thermal striping experiment using sodium. We also mention in closing that the transition from 2.25Hz to 0.7 Hz signifies a change in the namre of the flow. Although we plan to investigate this further the transition at z — 300 roughly corresponds to the axial location beyond v hich Fig. s and other video-images suggest a composite single-jet like structure

RMS reaches a quasi-constant magnitude equivalent to that of the single-jet.


5

Conclusions


An experiment investigating the thermal-hydraulic mixing of three quasi-planar, vertically flowing (water) jets was conducted. In the experiment the central jet was at a lower temperature than the two adjacent jets which were at the same temperature. The jets flowed into a large volume of water initially at the central jet's temperature. The average exit velocity (and flowrate) of the three jets was equal. Velocity measurements were taken using an ultrasound Doppler velocimeter while temperamre data were taken from an traversed array of thermocouples, The velocimeter yielded velocity profiles consisting of 128 points along its measurement line which were constructed from the echo signals received from ultrasound reflecting partiC1es moving with the flow. Except for some apparent difficulty in the echo signal processing (amplification) in the region close to the transducer both single- and triple-jet configurations yielded satisfactory velocity data. In fact a plot of the centerline decay velocity of our single-jet was in agreement with data extracted from past investigations. In addition velocity measurements yielded a measure of the flow fluctuations; that is, the standard deviation associated with the average velocity provided. in addition to the temperature data, a means of evaluating the turbulent nature of the flow and the mixing process.


.

As for the triple-.iet some expected similarities to the single-jet were observed, but generally the triple- jet exhibited an elevated level of fluctuations associated with the flow expressed in terms of the standard deviation of the veloci signal. In fact in comparison to the single-jet, nOrinalized RMS values were as much as 20 times as large in the region between the buoyant and non-buoyant (central)

jet. Beyond z

300 (zfi 10) however. due in part to thermal connective mixing of the jets, RMS of the single, isothermal jet exceeded the triple-jet. We thus partially concluded that for’ equal averas• je‹ exit velocities of U„ 0.5 m/s and a central-to-adjacent jet temperature difference IT = 5° (30°C and

25°C) fllOSt Of the convective mixing between the thermally-stratified jets occurs over an axial distance of z/D

2.0 to 4.5 where Dh' the hydraulic diameter of the exit nozzle. The mixing was on-average centered about the axis of the central jet and span a width, cD

2.25, In faGt mOSt Of the connective mixing takes place in the region defined by the edges OI the central jet and the right and left edges of

the adjacent jets; that is. in the regions in-between the cold and hot jets.


Finally a brief look into the spectral nature of the measured data revealed Evo primarily frequencies associated with the flow, these being a dominating frequency of 2.25Hz established within the first 80 mm from the exit and a lower frequency of 0,7 Hz appearing beyond a transition at approximately z 3ññ fRin dOWllStreaifl..r rt)FI4 {desk Fk3ii! v'ii *'iikk lp•d *o r••sor. that for o lnw Praridtl number fluid

such as sodium temperature fluctuations would more than likely occur at similar frequencies.


Acknowledgments

The author WOuld like to thank PLC for his appointment as PNC International Fellow. The authors also recognize the efforts at Mr. Ito and Mr. Onuma who diligently COnducted the experimental measurements, maintained the data and prepared the UVP and temperature data which were analyzed in order to prepare this report.


References

Betts C; Bourman C. Sheriff N (1983) Thermal striping in liquid metal cooled fast breeder reactors. 2nd Int'1 Topical Mtg, on Nuclear Reactor Thermal Hydraulics, NURETH-2, Santa Barbara. CA, USA. vol. 2, 1292-1301

Bannings 3 E (1982) LMFBR thermal-striping evaluation, Interim report, Rockwell International Energy Systems GrOup, Canoga Park, CA, USA . Research Project 1704-11. EPRI-NP-2672


Chereniisinoff N P (1986) ed. In: Encyclopedia of Fluid Mechanics, Dynamics at Single-Fluid FIOWS and Mixing, vol. 2, Houston. USA: Gulf Publishing Co.

Moriya S: Ushijima S; Tanaka N; Adachi S; Ohshima I (1991) Prediction of Thermal Striping in Reactors. Int'l Cpnf. Fast Reactors and Related Fuel Cycles, KyOto, Japan, Vol. 1. 10.6.1 - 10,6.10, Oct. 28 - Nov. 1


Murarnatsu T (199J) Development of thermohydraulics comput•‹ **E'arns for thermal striping phenomena, Specialists meeting on correlation between material properties and thermohydraulics

conditions in LMFRs, IAEA Working Group on Fast Reactors, 1WGF@ 90, Aix-en-Provence, France. November 22-24


Gebhardt B; Jaluria Y; Mahajan R L; Sammakia B (1988) In: Buoyancy-Induced Flows and Transport, Reference Edition. New York: Hemisphere Publishing Corporation


3“akeda Y (1986) Velocity profile measurement by ultrasound Doppler shift method. Int. J. Heat and Fluid Flow. 8:o lo-o 18

Takeda Y (1991a) Development of an ultrasound velocity profile monitor, Nucl. End. Design. 126: 277


Takeda V ; Kobayashi K (1991 b) Ultrasonic flow visualization of transient behavior of Taylor vortex flow. In: Experimental and Numerical Flow Visualization, ASME FED-128, 231

Tenchine D; Nam H-Y (1987) Thermal hydraulics of co-axial sodium jets, Am. Inst. Chem. Engrs. Symp. Ser. 83(257):! 51-156


Tenchine D ; Moro J-P (1995) Comparative analysis of sodium and air mixing jets experiments, 8th IAHR Working Group Mtg. Adv. Nuc1, React. Thermohydraulics, Rez, Czech Rep., June 13-15


Ultrasound Velocity Profile monitor (1992} Model X-1, Met-Flow SA, Lausanne, Switzerland Wood D S (1980) Proposal for design against thermal striping. Nuclear Energy. 19(6): 433-4 7


overflow pump

head tank

test

section

filter

heater

hot leg

air heat

exchanger

lab water supply tank

cold

leg

main loop

valve

Q turbine flowmeter

Figure 1. Schematic of experimental loop.


Top View plates window


JTerXow

chamber


2438


transducer


to head tank


2438 mm

overflow


traversing thermocouple array


285

i. measurement ,

region

hot cfild hot | 550


to head

tank



Not to scale!


Cold supply

Front View y=- Hot supply


Figure 2. Schematic of test section.


157


x ertically

traversing pillars

10 deg angle to horizonta

Thermocouple array

US beam line

›s.s

ground plane

“0” datum -° Not to scale!

5 mm 20mm

jet Cold jet Kot jet

Figure 3. Schematic of instrumentation set-up. Close-up of the UVP transducer orientation and

traversing thermocouple array.


Figure 5. A sequence of 9 snapshot images digitized from video of the triple-jet.


self-preserved velocity profile in the developed

Uctr„„ax


profile in’the entrainment ', mixing layer or occurs all

developing region along the

U, „q„ ; edge


mixing layers

core of the jet

jet exit

flat, square or top-hat velocity profile at exit

jet exit nozzle hydraulic diameter, Db


F,gure 6 Idealzed ve)ockyproG1es at ? axiallocations and a Quahtative sketch ofa plane bbulentjet. C/ Tennekesand Lnmley.


60

50

40 !

p z=45 z=95

g z=180

p z=275

;,; z=350

30 ” . - -- rhs-inverted

Rep„ exit 1.8 x 10 J$:i

20

t0

0

-10

-20

-30


!


0 20 40 60 81) 100 120 140

Spanwise distance, 0-12 7, total 284 mm


Figure 7a). Average velocity profile of the single-jet at selected axial locations.


peaked central region

z=45, avg-ve1

z=4 5 ;std-dev

edges of the jet

entrainment region; right

entrainment region; left

core region

approximate

location of exit

60 (

50

40

30

20


0

-10

,

-20


0 20 40 60 8.0 100 120 140

Spanwise dista nce, 0-1‹!7, total 284 mm


Figure 7b). Average velocity and standard deviation profiles of the single-jet at se1ecte‹l axial

distances.


u single-jet, Uo=40mm/s

— - Corrsin &Uberoi, :iir

- - - Warren, air

— - Kataoka, methane

, i i i

w .

i i i i

r r i i

i in- i

r i j i

i ,

,

i i i i

3



0

0 2 4 6 8 10 12 14 16

Dimensionless axial disltance, 'zfV


Figure 8. Axial decay of centerline velocity; a comparison. o!f single-and triple-jet data with past data.


100

80

60


Velocity,[ mm/s}

40

20


-20


-60


z=45

. . . . .

«=170

z=270

- z=.535

approximate location of hot cold hot jet exits

z es

0 20 40 60 8fl 100 120 140 !

Spanwise distance, 0-12”› , total 284 mm


Figure 9a). Average velocity profile of the triple-jet at selected axial locations.



4S td

S0


60


Velocity, [mm/s]

4fi


961

20


0


-20


-40


-60


20 40 60 8iO 100 120 140

Spanwise distance, 0-127,total 284 mm

Figure 9b). Average velocity and standard deviation profile:; of the triple-jet at selected axial locations.

asial location, z, along LM changes with steeper angles; compare z1 and z2



orientation is 10° to horizontal

Ideally of equal

magnitude


oppositel¡¡' entrained flow and oppositely directed vortices


On-average direction of entrained


LM-line of

measurement


Idealized profile


Figure 9c). Qualitative sketch of idealized triple-jet velocity profile and features.


197



90


80


70


60


Velocity, (mm/s]

50


40


30


20


10


-20


0 20 40 60 8fl 300 120 140

Spanwise distance, 0-127, total 284 mm

Figure 9d). Composite average velocity profile of triple-jet,


1.2


0.8


0.6


0.4


0.2


0 2 4 6 8 10

Axial distance, z/D

12 14 1h


Figure IN. Comparison of the normalized RMS for velocity ’versus axial distance, z/D, of single- and

triple-jets.

100

a), Region to., each 35.5 nor wide



100


— z=300/295

z=325/315

—325/335

«-. z=350/360


z=27S/270


0.1


1 2 3 4 5 6 7 8

p), Region ho., each 35.5 rixn wide '


1 2 3 4 5 6 7 8

Q), Region to., each 35.5 nan


100

z=120

r=70

o ’ O.1

2 3 4 S 6 7 8

e), on No., each 35.5 mii

1 2 3 4 5 6 7 8

Region No., each 35.5 mti

Figure 11a) - f). Spanwise distribution of the ratio of normalized RMS of the triple-jet to the single-jet as averaged regionally (1-8) and with the axial distance as a parameter.

2()()


32

31

30

28

27

z—120 z—70

26

25

- u - - z=500

0 20 40 60 80 100 120 140 16tl 180 200

Spanwise x-axis, [mm]



5

+ z=18O

+ z=40


o z=120

z 130


n z=300 '

2

Std. de*./ Tavgx 100 ,%

0 20 40 60 80 100 120 149 160 18tl 201)


Figute 13. Spanwise standard deviation of temperature ‹›f the triple-jet at selected axial locations.


2.5

2

0

‘ -


‘ ‘ ‘


'

+

0 100 200 300 400 500 6011 700 800 900 1000

Axial distance, z Jnim J


Fiure t4 Averag,standaid deviaionoftemperaN*eas«omaizedby!he averogeYersusaxia


20


Spanwise distance,x [mm]

40


60


80


120


140


160


50 100 150 200 250 309 350 400 450 500 550 600 65ß

Axial distance, z [mm]


Figure 15. Estimated turbulent heat flux distribution, (scale 0-360).



+ 1st-pk 2nd-pk

x 4tli-pk

c 5th-pk

— 6th-pk

10


Frequency

peak

I’d



0.01


0 100 200 300 400

Axial distance, z [mm}


500 6O